Commercial Electric Boiler
- These boilers are designed to connect water tanks and floor heating pipes, providing central heating and domestic hot water in real-time.
- They are suitable for large areas, and capable of handling extensive heating requirements efficiently.
- The boilers are designed for high-power applications, indicating their capability to handle significant heating demands.
Compact Design
Low-noise Operation
Safe Protection
Constant Temperature
Structure:
- The boilers are floor-standing units, given their high-power output and the need to heat large spaces.
- Their design probably emphasizes functionality and capacity, with a focus on reliability and durability to meet commercial heating demands.
Usage:
- These boilers are used for providing central heating and domestic hot water in large buildings and facilities.
- They are capable of efficiently managing the heating requirements of structures with significant space, such as schools and hotels.
Suitable Application Scenarios:
- Ideal for large commercial or institutional buildings like schools, hospitals, and hotels where consistent and reliable heating is necessary.
- Also suitable for commercial squares and factories, indicating their utility in industrial applications as well.
Different Series of Commercial Electric Boiler
Model | BL3158 | BL3200 | BL3320 | BL3415 | BL3456 |
Power (kW) | 158 | 200 | 320 | 415 | 456 |
Voltage (V) | 400 | ||||
Frequency (Hz) | 50/60 | ||||
Phase | 3 | ||||
Current(A) | 3*229 | 3*319 | 3*464 | 3*601 | 3*661 |
Wire(mm2) | ≥120 | ≥150 | ≥240 | ≥300 | ≥400 |
Working Temp. Range | 30°C~80°C (in radiator model) | ||||
30°C~60°C (in floor heating model) | |||||
Max. Water Temperature | 85°C | ||||
Temperature Difference Setting Range | 5~30°C | ||||
Antifreeze Start Temperature | <8°C | ||||
Antifreeze Stop Temperature | > 10°C | ||||
Output Voltage of Pump | 220Vac, 0.5A | ||||
Inlet & Outlet Connection | DN65(G2.5”) | 2*DN40(G1.5”) | 2*DN65(G2.5”) | 2*DN65(G2.5”) | 2*DN100(G4”) |
Backwater Inlet connection | DN65(G2.5”) | 2*DN40(G1.5”) | 2*DN65(G2.5”) | 2*DN65(G2.5”) | 2*DN100(G4”) |
Product Size(mm) | 1375*585*1420 | 1150*905*1640 | 1520*900*1656 | 1870*900*1675 | 2045*900*1675 |
Model | BG352 | BG378 |
Voltage (V) | 400 | |
Frequency (Hz) | 50/60 | |
Phase | 3 | |
Power (kW) | 52 | 78 |
Current (A) | 3*75.4 | 3*113 |
Wire (mm²) | ≥25 | ≥50 |
Application | school | office |
Circuit Breaker (A) | 100 | 160 |
Working Temp. Range | 30°C~80°C (in radiator model) | |
30°C~60°C (in floor heating model) | ||
Max. Water Temperature | 85°C | |
Temperature Difference Setting Range | 5~30°C | |
Antifreeze Start Temperature | <8°C | |
Antifreeze Stop Temperature | > 10°C | |
Output Voltage of Pump | 220Vac, 0.5A | |
Inlet & Outlet Connection | G1” | |
Backwater Inlet connection | G1 | |
Product Size | 490*485*960mm |